HNS Steam Generator Manual

 

Operating voltage 230 V–240 V 1N~/2~, (3.4 kW – 9.5 kW)
230 V 3~, (3.4 kW–14 kW)
400 V–415 V 3N~ (3.4 kW–14 kW)
 Output options  3.4 / 4.7 / 6.0 / 7.7 / 9.5 / 12.0 / 14.0 kW
 Enclosure class  IP 20
 Installation  Floor / Wall
 Water tank material  Aisi 304, stainless steel
Water tank pipes Aisi 314, acid-resistant stainless steel
Steamer dimensions 520 x 380 x 160 mm
Weight when empty about 11 kg

Easy to use

  • Floor or wall installation
  • Digital control panel Midi 2 (operating time can be set between 0–23 hours)
  • On/Off push button (alternative method of control, operating time fixed 30 min)
  • The installation of the control centre and On/Off push button in the steam room is allowed

Easy maintenance

  • Changeable resistors (3 pcs), of which 1 is fitted with a heat fuse.
  • Fill cap for chalk remover (citric acid) has been placed on the upper part of the steam generator.
  • Components easily replaceable, circuit board, heating elements, surface sensor.

Controls and accessories

  • Control panel Midi (0043256)
  • Sensor (0043210)
  • Automatic flush and rinse cycle. (Automatic drain valve 4310130)
  • Steam outlet
  • Light adapter (0043214)

Selecting the steam generator output for the steam room

You can estimate the power requirement using the formula below.
Volume (m3) x K1 x K2 = Power requirement (kW)

Forced ventilation K1 = 0.75
No ventilation K1 = 0.52
Acrylic wall K2 = 1.00
Light wall: board + tile K2 = 1.25
Heavy wall: stone, concrete + tile K2 = 1.50
Very heavy wall: stone, concrete + tile K2 = 2.00

In heavy built steam rooms, it is recommended to use e.g. electric heating cable for warming the seats, walls and floors.

Output Light structure, acrylic, tempered glass   Light board wall + tile   Heavy wall, concrete, stone   Steam kg/h
kW NoA/C Air conditioned No A/C Air conditioned No A/C Air conditioned  
3,4 2 – 7 m³ 2 – 6 m³ 2 – 6 m³ 2 – 5 m³ 2 – 5 m³ 2 – 4 m³ 5
4,7 3 – 8 m³ 3 – 7 m³ 3 – 7 m³ 2 – 6 m³ 2 – 6 m³ 2 – 5 m³ 6
6,0 4 – 13 m³ 4 – 9 m³ 4 – 8 m³ 3 – 7 m³ 3 – 7 m³ 3 – 6 m³ 8
7,7 6 – 15 m³ 6 – 11 m³ 6 – 10 m³ 5 – 9 m³ 5 – 9 m³ 4 – 8 m³ 10
9,5 9 – 17 m³ 9 – 13 m³ 9 – 14 m³ 8 – 13 m³ 7 – 11 m 6 – 9 m 13
12,0 12 – 24 m³ 11 – 18 m³ 11 – 20 m³ 9 – 16 m³ 9 – 16 m³ 8 – 12 m³ 16
14,0 18 – 30 m³ 14 – 22 m³ 14 – 24 m³ 12 – 18 m³ 11 – 17 m³ 10 – 14 m³ 19

Table for selecting a steam generator based on the steam room volume and wall materials.

 
 