Follow the safety clearance specifications when installing the sauna heater. Thin panel is not a suitable mounting base. The mounting base must be reinforced with timber behind the panel. The minimum clearances specified on page 8 must be followed also in case the sauna room wall materials are incombustible.

Walls or ceilings must not be clad with fibre-reinforced plaster board or other light-weight cladding, because they may cause a fire hazard.

A single sauna heater is allowed per a sauna room.

Sauna heater safety clearances

   

Safety Clearances

Effect Sauna Room Minimum distance to: Minimum distance for wall bracketf Minimum distance to niche Stone
kW Volume (m3) Height (mm)

Side wall A (mm)  In front of D (mm)  Ceiling F (mm) Floor K (mm)  B (mm)  J (mm)  E (mm)   n (kg)
3.0
4.5
6.0
8.0
9.0
2-4
3-6
5-9
8-13
9-14
1900
1900
1900
1900
1900
30
50
70
100
100
 50
80
100
150
200
 1200
1200
1250
1250
1250
120
120
120
120
120 
50
70
90
120
120 
 390
390
390
390
390
 540
580
650
750
-
15
15
23
23
23