Connection to mains

 

The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations. Sauna heater is connected with a semi-permanent connection. Use A07BB-F or H07RN-F (60245 IEC 66) cables or a corresponding type. Other output cables (signal lamp, electric heating toggle) must also adhere to these recommendations. Do not use PVC insulated cable as a connection cable for the sauna heater.

A multipolar (e.g. 7-pole) cable is allowed, if the voltage is the same. In the absence of a separate control current fuse, the diameter of all cables must be the same, i.e. in accordance with the front fuse.

The connecting box on the sauna wall should be located within the minimum safety clearance specified for the sauna heater. The maximum height for the connection box is 500 mm from the floor. If the connection box is located at 500 mm distance from the heater, the maximum height is 1000 mm from the floor

Adhere to the effective electrical safety regulation when installing the sauna heater.

Power (kW)  Power supply cable H07RN-F / 60245 IEC 66 (mm2) 400V – 415V 3N~ Fuse A  Power supply cable H07RN-F / 60245 IEC 66 (mm2) 230V 3~ Fuse A Power supply cable H07RN-F / 60245 IEC 66 (mm2) 230V – 240V 1N~ / 2~ Fuse A
3.0
4.5
6.0
8.0
9.0
5 x 1.5
5 x 1.5
5 x 1.5
5 x 2.5
5 x 2.5
 3 x 10
3 x 10
3 x 10
3 x 16
3 x 16
4 x 1.5
4 x 2.5
4 x 2.5
4 x 6
4 x 6 
3 x 10
3 x 16
3 x 16
3 x 25
3 x 25 
 3 x 2.5
3 x 4.0
3 x 6.0
3 x 6.0
- - -
 1 x 16
1 x 20
1 x 35
1 x 35
- - -